Build Transport Device
- Electrode Setting
- Left electrode: must be a structure with lattice
- Number of left electrode: 3-7, default is 5
- Right electrode: must be a structure with lattice
- Number of right electrode: 3-7, default is 5
- Central Region Setting
- Central structure: must be a structure with lattice
- Left boundary of central region: When constructing the transport device, the part of the central structure which fractional coordinate is less than this value will be removed
- Right boundary of central region: When constructing the transport device, the part of the central structure which fractional coordinate is greater than this value will be removed
- Keep left boundary atoms: When selected, the atoms of the central structure which fractional coordinates are exactly equal to 'left boundary of central region' will be keeped
- Keep right boundary atoms: When selected, the atoms of the central structure which fractional coordinates are exactly equal to 'right boundary of central region' will be keeped
- Left boundary of external potential: The left starting position of the bias
- Right boundary of external potential: Right starting position of the bias
NOTE:
Note: The stitching direction is along the first lattice basis vector direction. The current direction follows the -a vector direction